CUS 3D Manhole Survey & Inspection
We offer CUS Manhole Surveying and Inspection Services with our patented CUS surveying system (pat. no. 397.432).
Additional Information
Specification
Accuracy
- X/Y coordinates +/- 5 cm
- Z coordinates +/- 1 cm
- Diameter of profile+/- 1 cm
- Lengths +/- 3 cm
- Junction +/- 2°
Inspection Data
- X/Y/Z coordinates in national coordinate system of mean point of manhole, center point of manhole, base center point of manhole
- X/YZ coordinates in national coordinate system of junction point of inlet and outlet pipes
- Direction of inlet and outlet pipes
- Profile shape and dimensions of inlet and outlet pipes
- Diameter of round shapes, corner coordinates X/Y of square and rectangle shapes
- Material of manhole and connection pipes
- Capture of constructional damages according to ATV M143-2 or EN13508-2
- Connection pipes according to ATV M143 (e.g. housing pipes, industrial pipes, drainages) are captured and surveyed in national coordinate system
- Documentation and inspection report with key, localization and structural data according to national coding system (e.g. ATV, EN13508-2, ISYBAU)
- Manhole sketch in 2D/3D
Digital Data Transfer
- Digital damage pictures as JPEG
- Manhole sketch in 2D/3D view in AutoCAD DWG or DXF drawing
- Manhole inspection data (structural, geometrical and connections/damages informations) as flat ASCII file format with X/Y/Z coordinates, directions and structural informations or as ISYBAU file format 2001 type K/S/V or customer preferences
- Inspection report as digital PDF document